Home > Your application > Metals, alloys
Metals, alloys
Challenges of new metals and alloys |
|
|
Thermal Analysis is an essential tool as it allows access to: -Data on thermodynamics and kinetics, including temperature and heat of melting and crystallisation, heat capacity, expansion coefficient, etc. - Stability and resistance in relation to temperature, atmosphere, etc.: oxidation, reduction, corrosion, etc. Thermal Analysis also allows simulation of processes (sintering, for instance) and measurement of heat of dissolution. |
![]() |
SETARAM offers specially designed systems |
|
|
With its High-Sensitivity and High-Temperature (up to 2400°C) Thermal Analyzers, SETARAM offers a wide range of systems that are specially designed for R & D on metals and alloys. Additional accessories and systems allow thermal measurements in special atmospheres (oxidative, damp, corrosive, etc.). |
|
| Brochure | |
High-performance modular thermal analyzers (ambient / 2400°C) |
||
|
Widest temperature range (-150 / 2400°C) on the market Modularity: the different modules DTA, DSC, TGA, TMA can be adapted interchangeably around the same structure Measurement performance: satisfy unique resolution, precision and sensitivity criteria SETSYS Evolution is today the state-of-the-art in research-grade thermal analyzers. It includes: -SETSYS Evolution DTA (up to 2400°C), DSC (up to 1600°C) -SETSYS Evolution TGA -SETSYS Evolution simultaneous TGA-DTA/DSC-EGA -SETSYS Evolution TMA SETSYS Evolution DTA/DSCSETSYS Evolution TGASETSYS Evolution TGA-DTA/DSCSETSYS Evolution TMA |
|
Large volume thermal analyzers (ambient / 2100°C) : Calorimeter, DTA/DSC, TGA-DTA/DSC, TMA |
||
|
96 LINE, a modular line of high-temperature (ambient - 2100°C) and large-volume thermal analyzers Large sample volume: for analysing bulky, massive and non-dissociable samples (e.g. corrosion studies of mechanical parts, etc), for working on mixed materials (concrete core sample), for detecting very weak variations of mass in TGA (corrosion studies on sheet steel, etc.) Modularity: the different calorimeter modules (DTA, DSC, TGA, TMA) can be adapted interchangeably around the same structure 96 Line includes: - MHTC 96 for calorimetric (drop) and DSC measurements - DTA, DSC 96 - TGA 96 for thermogravimetric and simultaneous TGA and DSC/DTA measurements - TMA 96 MHTC 9696 Line DTA / DSC96 Line TGA96 Line TGA - DTA / DSC96 Line TMA |
|
TGA, DTA, DSC and Simultaneous TGA-DTA, TGA-DSC from ambient to 1600°C |
||
|
LABSYS evo- Coupling to gas analysis (FTIR, MS) - New 3D high-precision Cp sensor - Cp measurement within 2 % up to 1600 °C - Calisto software LABSYS evo offers TGA with simultaneous DTA or DSC and Cp measurement within the temperature range of ambient to 1 600 °C. The LABSYS evo features a NEW high performance top loading balance and a unique 3D high-precision (Calvet type) Cp rod. Thanks to its unique ergonomic design and market leading Calisto software the LABSYS evo offers you the most easy-to-use Thermal Analysis system with uncompromised performance. See more. |
|
High Performance Symmetrical TGA System (ambient / 1750°C) |
||
|
TAGThe TAG Analyzers use a symmetrical balance mounted over two matched furnaces to allow for buoyancy free measurements. This allows, primarily, for almost zero baseline drift and therefore for high precision and long term experimental studies. An example is the long term oxidation of metals and specialist materials. Additionally the furnaces are easily adapted to take highly corrosive gaseous mixtures, and a fully automated gas panel allows for mixing and control for precise simulation of even the most demanding environments. See more. |
|
An innovative line of Thermal Analyzers (-120 / 830°C) with 3D-Inside technology: DSC, High Pressure DSC, Robot DSC, TG-DSC-EGA |
||
|
The SENSYS evo offers the most precise DSC sensor together with a truly symmetrical microbalance to give YOU a combined TG-DSC system with totally unmatched performance. Additionally both measurement sensors are totally independent,so can be operated independently or simultaneously without compromising performance. SENSYS evo can be used in various configurations: - DSC in horizontal or vertical mode - High Pressure DSC(up to 500 bars at 600°C) - Robotic DSC, with 48 samples, even under pressure - Simultaneous TG-DSC-coupling to gas analysis (BET, gas sorption, FTIR, MS) SENSYS evo DSCSENSYS evo TG-DSC |
|
More Thermal Conductivity Testing in less time |
||
|
TCiThe C-Therm Technologies TCi is truly a 'one size fits all' thermal conductivity tool. No other instrument can test solids, liquids, powders, and pastes. Within a material type, the technology has the attributes necessary as a lab tool to accelerate your research & development efforts or improve your quality control. As an added bonus, the technology can be migrated to the shop floor to gain insights into your production processes. See more. |
|
An-easy-to-use Differential Scanning Calorimeter DSC (-170 to 700°C) with a 3-year warranty |
||
|
DSC131 evoDSC131 evo: for testing, QC and academic thermal analysis laboratories. An instrument designed from the ground up to be robust, high performance and above all user friendly featuring market leading intuitive CALISTO software and low operating costs. See more. |
|
Controlled Humidity Generator |
||
|
WetsysHumidity is known to have a significant influence on the stability of many materials. The controlled humidity generator WETSYS can: - deliver a very precise level of relative humidity (RH) from 5 to 95% depending on the temperature - be connected to other SETARAM instruments, and in particular to the SENSYS TG DSC as well as other analysis instrument (RX, GC, etc.) for studies of sorption, hydration, stability, etc. See more. |
|
Unique automated Quality/Control instrument for determination of σs for ferromagnetic compounds |
||
|
Sigmameterσs: Specific saturation magnetizationThe magnetic specifications of ferromagnetic compounds can vary widely as a result of mechanical and/or thermal treatments. Specialists make us of these variations in magnetic specification to study the evolution of some solid state transitions. Magnetic measurements offer high sensitivity and allow the detection of very subtle metallurgical events. See more. |
|
High Temperature Calvet Calorimeter (up to 800 / 1000°C) |
||
|
AlexSysThe AlexSys is a high-sensitivity Calvet calorimeter optimized for high temperature solution calorimetry in molten solvents at temperatures to 1000 °C. The AlexSys is based on Prof. Alexandra Navrotsky’s (University of California - Davis) High Temperature Calorimeter which has many years of development, use, and application. See more. |
|
Application Documents
Articles
|
See articles |
Brochure
|
Download |
Register now
for full access to applicationlibrary,spare parts catalog and newletters
Contact us
Contact us
Our news
NEW PRODUCT: PCTPro E&E
A fully automated Sievert instrument for measuring Gas (CO2, CH4, C2H6, N2) Sorption properties of materials.
CO2 CAPTURE & SEQUESTRATION
Find out how our instrumentation is used to study CO2 Capture and Sequestration NEW PRODUCT
Introduction of a new autosampling option for LABSYS, market leading TGA, STA and TG-DSC
Our agenda
- November 03, 2010 - November 03, 2010
BATTERY SAFETY 2010
Boston, MA - USA
We will also be holding a workshop on November 4th entitled:
An Introduction to Assesment of Batteries & Materials Using Calorimetry and Thermal Analysis
A seminar designed to help understand the applications of calorimetry and thermal analysis in the assessment of batteries, cells and materials development. This includes everything from screening materials, to self discharge and of course abuse and overcharge testing.
The agenda is a series of presentations that introduce the techniques, principles of operation and key measurement capabilities of different techniques as well as a review of data and publications in the recent months that describe experimental procedures being applied today throughout the battery world. - October 18, 2010 - October 22, 2010
MATERIAUX 2010
Nantes, FRANCE
Stand 23
Co-organized by more twenty learned societies, these events have been meeting opportunities between the national actors in the various fields of Materials Science.
For this 3rd edition, 14 symposiums are proposed whose:
- Civil engineering and Futur Habitat
- Energy Storage & Conversion
- Materials for Transport
- Materials & Environment
- Nanochemistry, Nanomatérials, Nanostructures
- Materials and Health Safety
- Thermodynamics and Materials for High Temperatures
- Mechanical properties and Spoiling
- Material stakes for the nuclear reactor (generation IV) - September 05, 2010 - September 08, 2010
MOF'S Conference
Marseille, FRANCE
This conference will follow the very successful 2008 conference that was held in Augsburg. The conference 2010 will be organized in Marseille at a central location overlooking the old port. The aims of MOF2010 are to address all questions concerning the community working with Metal Organic Frameworks, Metal Coordination Compounds and related materials. The spectrum of topics to be treated range from synthesis and characterization of new materials to properties of materials towards potential applications in biology/medicine, catalysis, magnetism, luminescence and sorption. Both experimental and theoretical aspects will be dealt with, along with key questions pertaining to potential industrial applications of this fascinating family of materials. - September 05, 2010 - September 10, 2010
SCTE 2010
Annecy, FRANCE
17th International Conference on Solid Compounds of Transition Elements
SCTE 2010 will be held in Annecy September, 5-10, 2010. The conference will be jointly organized by Institut Néel, CNRS-Université Joseph Fourier, Grenoble and Institut de Chimie de la Matière Condensée de Bordeaux, CNRS- Université Bordeaux 1, Bordeaux.
Useful Links